A steel pipe schedule chart maps Nominal Pipe Size (NPS) to exact wall thickness across standardised thickness designations โ from thin-walled SCH 10 up to heavy-walled SCH 160 and XXS. Use the tables below to check dimensions, weight and selection limits before you write a specification.
In piping engineering, "Schedule" (SCH) is a dimensionless wall-thickness series defined by ASME B36.10M for carbon and alloy steel, and ASME B36.19M for stainless steel. It is not a pressure rating in PSI, and it is not a measurement in millimetres.
For any given NPS, the Outside Diameter (OD) stays constant regardless of schedule. A higher schedule number increases wall thickness and reduces the Inside Diameter (ID). That single rule explains most of the confusion around schedule tables โ and most of the ordering errors we see in RFQs.
Table of Contents
Master Steel Pipe Schedule Chart (Wall Thickness in mm & Inches)
The table below covers the most frequently specified schedules across NPS 1/2" to 24" per ASME B36.10M. Values are shown as millimetres followed by inches. An em dash means that schedule is not defined for that size in the standard โ it is not a zero wall.
Two equivalences are worth memorising: STD (Standard) matches SCH 40 up to NPS 10", and XS (Extra Strong) matches SCH 80 up to NPS 8". Beyond those sizes the designations diverge, which is where most catalogue errors originate.
↔ Scroll the table sideways to see every schedule from SCH 10 to XXS.
| NPS (in) | DN (mm) | OD (mm) | SCH 10 | SCH 20 | SCH 30 | SCH 40 | STD | SCH 60 | SCH 80 | XS | SCH 120 | SCH 160 | XXS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1/2" | 15 | 21.3 | 2.11 / 0.083 | — | — | 2.77 / 0.109 | 2.77 / 0.109 | — | 3.73 / 0.147 | 3.73 / 0.147 | — | 4.78 / 0.188 | 7.47 / 0.294 |
| 3/4" | 20 | 26.7 | 2.11 / 0.083 | — | — | 2.87 / 0.113 | 2.87 / 0.113 | — | 3.91 / 0.154 | 3.91 / 0.154 | — | 5.56 / 0.219 | 7.82 / 0.308 |
| 1" | 25 | 33.4 | 2.77 / 0.109 | — | — | 3.38 / 0.133 | 3.38 / 0.133 | — | 4.55 / 0.179 | 4.55 / 0.179 | — | 6.35 / 0.250 | 9.09 / 0.358 |
| 1-1/4" | 32 | 42.2 | 2.77 / 0.109 | — | — | 3.56 / 0.140 | 3.56 / 0.140 | — | 4.85 / 0.191 | 4.85 / 0.191 | — | 6.35 / 0.250 | 9.70 / 0.382 |
| 1-1/2" | 40 | 48.3 | 2.77 / 0.109 | — | — | 3.68 / 0.145 | 3.68 / 0.145 | — | 5.08 / 0.200 | 5.08 / 0.200 | — | 7.14 / 0.281 | 10.15 / 0.400 |
| 2" | 50 | 60.3 | 2.77 / 0.109 | — | — | 3.91 / 0.154 | 3.91 / 0.154 | — | 5.54 / 0.218 | 5.54 / 0.218 | — | 8.74 / 0.344 | 11.07 / 0.436 |
| 2-1/2" | 65 | 73.0 | 3.05 / 0.120 | — | — | 5.16 / 0.203 | 5.16 / 0.203 | — | 7.01 / 0.276 | 7.01 / 0.276 | — | 9.53 / 0.375 | 14.02 / 0.552 |
| 3" | 80 | 88.9 | 3.05 / 0.120 | — | — | 5.49 / 0.216 | 5.49 / 0.216 | — | 7.62 / 0.300 | 7.62 / 0.300 | — | 11.13 / 0.438 | 15.24 / 0.600 |
| 4" | 100 | 114.3 | 3.05 / 0.120 | — | — | 6.02 / 0.237 | 6.02 / 0.237 | — | 8.56 / 0.337 | 8.56 / 0.337 | 11.13 / 0.438 | 13.49 / 0.531 | 17.12 / 0.674 |
| 6" | 150 | 168.3 | 3.40 / 0.134 | — | — | 7.11 / 0.280 | 7.11 / 0.280 | — | 10.97 / 0.432 | 10.97 / 0.432 | 14.27 / 0.562 | 18.26 / 0.719 | 21.95 / 0.864 |
| 8" | 200 | 219.1 | 3.76 / 0.148 | 6.35 / 0.250 | 7.04 / 0.277 | 8.18 / 0.322 | 8.18 / 0.322 | 10.31 / 0.406 | 12.70 / 0.500 | 12.70 / 0.500 | 18.26 / 0.719 | 23.01 / 0.906 | 22.23 / 0.875 |
| 10" | 250 | 273.1 | 4.19 / 0.165 | 6.35 / 0.250 | 7.80 / 0.307 | 9.27 / 0.365 | 9.27 / 0.365 | 12.70 / 0.500 | 15.09 / 0.594 | 12.70 / 0.500 | 21.44 / 0.844 | 28.58 / 1.125 | 25.40 / 1.000 |
| 12" | 300 | 323.9 | 4.57 / 0.180 | 6.35 / 0.250 | 8.38 / 0.330 | 10.31 / 0.406 | 9.53 / 0.375 | 14.27 / 0.562 | 17.48 / 0.688 | 12.70 / 0.500 | 25.40 / 1.000 | 33.32 / 1.312 | 25.40 / 1.000 |
| 14" | 350 | 355.6 | 6.35 / 0.250 | 7.92 / 0.312 | 9.53 / 0.375 | 11.13 / 0.438 | 9.53 / 0.375 | 15.09 / 0.594 | 19.05 / 0.750 | 12.70 / 0.500 | 27.79 / 1.094 | 35.71 / 1.406 | — |
| 16" | 400 | 406.4 | 6.35 / 0.250 | 7.92 / 0.312 | 9.53 / 0.375 | 12.70 / 0.500 | 9.53 / 0.375 | 16.66 / 0.656 | 21.44 / 0.844 | 12.70 / 0.500 | 30.96 / 1.219 | 40.49 / 1.594 | — |
| 18" | 450 | 457.2 | 6.35 / 0.250 | 7.92 / 0.312 | 11.13 / 0.438 | 14.27 / 0.562 | 9.53 / 0.375 | 19.05 / 0.750 | 23.83 / 0.938 | 12.70 / 0.500 | 34.93 / 1.375 | 45.24 / 1.781 | — |
| 20" | 500 | 508.0 | 6.35 / 0.250 | 9.53 / 0.375 | 12.70 / 0.500 | 15.09 / 0.594 | 9.53 / 0.375 | 20.62 / 0.812 | 26.19 / 1.031 | 12.70 / 0.500 | 38.10 / 1.500 | 50.01 / 1.969 | — |
| 24" | 600 | 609.6 | 6.35 / 0.250 | 9.53 / 0.375 | 14.27 / 0.562 | 17.48 / 0.688 | 9.53 / 0.375 | 24.61 / 0.969 | 30.96 / 1.219 | 12.70 / 0.500 | 46.02 / 1.812 | 59.54 / 2.344 | — |
Source: ASME B36.10M welded and seamless wrought steel pipe. Table shows nominal wall thickness. Permitted mill tolerance is separate โ see the boundary conditions section below.
Engineering note: from NPS 14" onward, the nominal size equals the actual outside diameter in inches (NPS 14" = 14.000 in / 355.6 mm). Below 14" the NPS is a legacy designation and does not equal the OD โ NPS 2" pipe measures 60.3 mm.
Pipe outside diameter, wall thickness and weight per metre for larger API 5L line pipe sizes are specified individually rather than by schedule. If your project runs above NPS 24", see the dimensional tables on our LSAW steel pipe specifications page.
Steel Pipe Weight Chart by Schedule (kg/m & lb/ft)
Freight cost, crane capacity and structural support loads all depend on pipe mass per unit length. Plain-end carbon steel pipe weight follows from geometry alone:
The constant 0.0246615 already includes π/4 and the density of carbon steel. For stainless steel, substitute a lower density factor (approximately 0.0248 for 304/316 at 7.93–8.00 g/cm³) โ the geometry term is unchanged.
| NPS (in) | OD (mm) | SCH 10 | SCH 40 | SCH 80 | SCH 160 | XXS |
|---|---|---|---|---|---|---|
| 1/2" | 21.3 | 1.00 / 0.67 | 1.27 / 0.85 | 1.62 / 1.09 | 1.95 / 1.31 | 2.55 / 1.71 |
| 1" | 33.4 | 2.09 / 1.40 | 2.50 / 1.68 | 3.24 / 2.17 | 4.24 / 2.85 | 5.45 / 3.66 |
| 2" | 60.3 | 3.93 / 2.64 | 5.44 / 3.65 | 7.48 / 5.02 | 11.11 / 7.46 | 13.44 / 9.03 |
| 3" | 88.9 | 6.45 / 4.33 | 11.29 / 7.58 | 15.27 / 10.25 | 21.35 / 14.34 | 27.68 / 18.58 |
| 4" | 114.3 | 8.36 / 5.61 | 16.07 / 10.79 | 22.32 / 14.98 | 33.54 / 22.51 | 41.03 / 27.54 |
| 6" | 168.3 | 13.84 / 9.29 | 28.26 / 18.97 | 42.56 / 28.57 | 67.56 / 45.35 | 79.22 / 53.16 |
| 8" | 219.1 | 19.96 / 13.40 | 42.55 / 28.55 | 64.64 / 43.39 | 111.27 / 74.69 | 107.92 / 72.42 |
| 10" | 273.1 | 27.78 / 18.65 | 60.29 / 40.48 | 95.84 / 64.33 | 172.33 / 115.67 | 155.15 / 104.13 |
| 12" | 323.9 | 35.98 / 24.16 | 79.73 / 53.52 | 132.08 / 88.63 | 238.76 / 160.27 | 186.97 / 125.49 |
| 16" | 406.4 | 62.64 / 42.05 | 123.30 / 82.77 | 203.53 / 136.61 | 365.35 / 245.25 | — |
| 20" | 508.0 | 78.55 / 52.73 | 183.42 / 123.11 | 311.17 / 208.87 | 558.13 / 374.66 | — |
| 24" | 609.6 | 94.46 / 63.41 | 254.95 / 171.13 | 442.08 / 296.77 | 808.22 / 542.55 | — |
Values are kg/m followed by lb/ft for plain-end pipe at nominal wall thickness. Couplings, coatings and end preparations add weight and are quoted separately.
Weight differences between schedules are larger than most buyers expect. A 12" line in SCH 40 weighs 79.7 kg/m; the same line in SCH 160 weighs 238.8 kg/m โ three times the steel, three times the freight, and a different crane class for handling. That is why over-specifying a schedule is a cost decision, not a safety margin.
For fire protection systems, where weight and hydraulic performance are both governed by NFPA and UL/FM listings rather than by ASME schedules, see fire sprinkler steel pipe.
Common Misconception: Pipe Schedule Does NOT Equal Pressure Rating
A widespread error in procurement RFQs is treating the schedule number as a fixed pressure limit โ assuming, for instance, that "SCH 40 always handles 40 bar", or that two different sizes of SCH 40 pipe hold the same pressure. Neither is true.
A smaller-diameter pipe of the same schedule holds significantly higher internal pressure than a larger-diameter pipe. Under Barlow's formula, internal yield pressure is proportional to the wall-thickness-to-diameter ratio (t/D), not to wall thickness alone:
- 1" SCH 40 (ASTM A106 Gr. B): with a 3.38 mm wall and 33.4 mm OD, t/D = 0.101. Allowable working pressure exceeds 2,500 PSI at ambient temperature.
- 12" SCH 40 (ASTM A106 Gr. B): even though its wall is three times thicker at 10.31 mm, its 323.9 mm OD gives t/D = 0.032. Allowable working pressure drops below 950 PSI.
Same schedule number, same material, same temperature โ a pressure capability difference of more than 2.5 times. Anyone specifying "SCH 40, working pressure 40 bar" without stating the diameter is leaving the most important variable undefined.
Beyond geometry, actual pressure containment depends on material yield strength (ASTM A53 Gr. A versus API 5L X65), temperature derating, weld joint efficiency (E = 1.0 for seamless versus 0.85 for ERW in certain ASME code cases) and corrosion allowance. Our ERW manufacturing guide covers how the weld seam and its inspection affect that joint efficiency factor.
Carbon Steel vs. Stainless Steel Schedules (ASME B36.10M vs. B36.19M)
When ordering corrosion-resistant piping, never assume stainless wall thicknesses match carbon steel schedules at every size. Stainless schedules carry an "S" suffix โ SCH 5S, 10S, 40S, 80S โ and are defined by a separate standard, ASME B36.19M.
The two series are identical for small sizes and diverge as diameter grows. SCH 40S matches STD at every size; SCH 10S and SCH 80S stop thickening once they reach a fixed wall, while their carbon counterparts keep climbing.
| Feature | ASME B36.10M (Carbon & Alloy) |
ASME B36.19M (Stainless) |
|---|---|---|
| Designations available | SCH 10, 20, 30, 40, STD, 60, 80, XS, 100, 120, 140, 160, XXS | SCH 5S, 10S, 40S, 80S |
| SCH 10 vs. 10S | Thickens with size — 12" SCH 10 = 4.57 mm | Caps out — 12" SCH 10S = 4.57 mm, but 14" SCH 10S = 4.78 mm against 6.35 mm for SCH 10 |
| SCH 40 vs. 40S | Diverges from NPS 12" upward — 12" SCH 40 = 10.31 mm | Matches STD at all sizes — 12" SCH 40S = 9.53 mm |
| SCH 80 vs. 80S | Diverges from NPS 10" upward — 10" SCH 80 = 15.09 mm | Matches XS at all sizes — 10" SCH 80S = 12.70 mm |
| Typical manufacturing route | ERW up to SCH 80; seamless for SCH 40 and heavier | Welded for 5S–40S; seamless for 10S–80S |
Practical consequence: a 14" stainless line ordered as "SCH 10" against a carbon steel reference will arrive at 4.78 mm instead of 6.35 mm. On a pressure-critical line that is a silent 25% loss of wall. Specify the standard, not just the schedule โ see stainless steel pipe for the sizes and grades we supply.
Application Match & When Standard Schedules Should NOT Be Used
Starkpipes manufactures and supplies carbon and alloy steel pipe across standard schedules from SCH 10 to XXS โ covering ERW, seamless and fire protection lines โ so engineers can match wall thickness to operating pressure, jointing method and jobsite inspection rules without over-specifying steel weight.
Typical Industry Applications by Schedule
- SCH 10 / Light-Wall: low-pressure water distribution, HVAC chilled water loops and UL/FM-listed fire sprinkler systems joined by roll-grooved couplings, where cut-threading is prohibited because of the thin wall.
- SCH 40 / STD: the baseline choice for commercial plumbing, low-to-medium pressure steam, compressed air headers and structural bollards.
- SCH 80 / XS: threaded process piping โ thread cutting removes roughly 1.5โ2.0 mm of wall โ chemical plant lines and medium-pressure hydraulic return lines.
- SCH 120 / 160 / XXS: high-pressure steam generation, refinery hydrocracking units, wellhead injection lines and heavy mechanical sleeves.
For casing and tubing in oilfield service, wall thickness is governed by API 5CT collapse and burst ratings rather than by ASME schedules โ the two systems do not cross-reference cleanly. See the OCTG supplier guide for how those ratings are specified and verified.
When Standard Schedule Charts Are Not Enough
Do not rely strictly on standard schedule designations in the following scenarios:
- Large-diameter transmission pipelines (NPS 26" and above). Above NPS 24", ASME B36.10M offers very few schedule numbers โ mainly SCH 10, 20, STD, 30 and XS. Oil and gas transmission projects under API 5L specify exact custom wall thicknesses in millimetres (for example 1219 mm OD × 14.3 mm WT) rather than schedule codes.
- High-temperature creep and high-pressure boiler service. In power plant main steam headers above 450°C (842°F), engineers calculate minimum required wall thickness per ASME B31.1 and then add mill under-tolerance plus corrosion allowance โ often arriving at custom heavy walls thicker than XXS.
- Strict negative tolerance projects. Standard ASTM/ASME specifications allow up to −12.5% wall thickness tolerance on seamless pipe. If your EPC specification enforces −0% or −5%, ordering nominal "SCH 80" without stating minimum wall thickness (MWT) will produce rejected lots at inspection.
Ordering note: write the schedule and the MWT. "24 in, SCH 80, API 5L X65 PSL2, MWT 28.0 mm" is a specification. "24 in SCH 80" is a starting point for a conversation about which mill tolerance you can accept.