Gasoducto Andino del Sur
Peru · 2025 · High-strength LSAW line pipe for a natural gas transmission pipeline in the Andean highlands
- Volume763 MT
- Diameter813 mm (32 in)
- GradeX65 PSL2
- Wall17.64 mm
The requirement
The Gasoducto Andino del Sur project required high-strength LSAW line pipe for natural gas transmission across Peru's mountainous terrain. The 813 mm (32-inch) diameter and API 5L X65 PSL2 grade were specified to handle elevated operating pressures while minimising wall thickness — a critical factor given the logistical challenges of transporting pipe to high-altitude construction sites.
PSL2 was chosen over PSL1 for its tighter toughness and chemistry requirements, which are essential for pipelines operating through regions with significant temperature variation between day and night at Andean altitudes. The 17.64 mm wall thickness balanced pressure containment with weight considerations for mountain transport.
Scope of Supply
| Product | LSAW line pipe, JCOE formed |
|---|---|
| Standard | API 5L (46th edition) / ISO 3183, PSL2 |
| Grade | X65 (L450) PSL2 |
| Outside diameter | 813 mm (32 in) |
| Wall thickness | 17.64 mm |
| Length | 12 m nominal, random 11.5–12.2 m |
| Pipe ends | Bevel 30° +5°/0°, plain ends, per API 5L 9.8 |
| Hydrostatic test | Per API 5L 9.4, 100% mill hydrostatic |
| Non-destructive testing | 100% UT on the weld seam, per API 5L 9.6 |
| CVN impact test | Per PSL2 requirement, tested at design temperature |
| Documentation | EN 10204 3.1 mill certificates, heat-number traceability |
| Total quantity | 763 MT |
How It Was Manufactured
Plate inspection
X65 PSL2 plate checked by UT, with chemistry, tensile and CVN impact properties verified against API 5L PSL2 requirements before forming.
JCOE forming and welding
Plate crimped, J-formed and O-pressed, then SAW welded inside and outside. Mechanical expander restores ovality and circumference to PSL2 tolerance.
Testing
Every joint hydrostatically tested per API 5L 9.4, weld seam scanned by 100% UT per API 5L 9.6. CVN impact tested per PSL2 requirement.
End prep and dispatch
Bevel applied, end protectors fitted, heat number stencilled for field traceability. EN 10204 3.1 certificates issued per lot.
Delivery Schedule
Order confirmed
Technical specification, PSL2 testing plan and inspection requirements approved with the project owner.
Production
X65 PSL2 LSAW pipe produced with chemistry and toughness controlled per heat. CVN impact tested at design temperature.
Inspection
100% UT, hydrostatic test, dimensional verification. EN 10204 3.1 certificates and heat traceability records prepared.
Shipment
Loaded and shipped to Peru, coordinated with the highland construction season and mountain transport logistics.
What Made the Difference
- PSL2 toughness at altitude. The Andean route subjects pipe to large temperature swings. PSL2 chemistry control — with CVN impact testing at the design temperature — ensured the pipe would perform reliably in cold high-altitude conditions where brittle fracture is a risk.
- High strength, optimised weight. X65 grade allowed a thinner wall (17.64 mm) compared to lower grades at the same pressure, reducing total tonnage and easing the logistics of transporting pipe to high-altitude sites by mountain road.
- Complete traceability. Each joint carries a heat number linking plate, weld and hydrostatic records, enabling the project owner to verify any pipe during construction without additional testing.
Related Work
Other case studies
Technical guide
Browse all project case studies · the steel pipe FAQ.
Planning a highland gas pipeline?
Send us the operating pressure, route profile and design temperature — we will confirm the grade, wall thickness and PSL level.